Thursday, October 17, 2019

BCA Compliance Engineering and Construction Essay Assignment

BCA Compliance Engineering and Construction Essay - Assignment Example The building is located in a town center. 1.2 LIMITATIONS Limitations applied to the document are: No consideration for a detailed requirement for the Australian standards Construction safety act have not been looked at A complete architectural design for the structure not available and The provisions made for the disabled. 1.3 DESIGN DOCUMENTATION The report is based on the design brief and the set of preliminary drawings. Drawing1 Building illustration Drawing 2 Front Elevation of completed structure Drawing 3 Ground floor plan Drawing 4 Basement plan PART 2 BUILDING CHARACTERISTICS BCA Classification Class 7a: Car park and warehouse CLASS 7b: for storage, or display of goods or produce for sale by wholesale. Rise in Storey Five(5) Type of Construction Type A Effective Height Less than 25 meters. Fire Compartment Size Floor Area: 3600 square meters Volume: does not exceed the minimum stated in BCA PART 3: BCA ASSESSMENT 3.1 METHODOLODY The design provided is to be audited against t he Deemed-to- Satisfy Provisions of the Building Code of Australia, 2010(BCA). The areas discussed have been assessed to meet the performance based solutions: 3.2.0 Fire Resistance For fire stability of the structure, the BCA requires its resistance and stability, the compartments and modes of separation as well as the allowances made for protection against fire. 3.2.1 Fire Resistance and Stability The structure constructed should remain stable during fire to allow evacuation. Its elements should resist any spread of fire. This must comply with the purpose of the structure, intensity of the fire, the fire systems in place, size of the fire compartment and any interventions made by the fire brigade. The material used for the building must limit smoke produced when the building is burning. The fumes produced should not be toxic so as to allow the occupants to evacuate the building. 3.2.2 Compartment and Separation The floor area should be greater than the atria. An open area should be available near the building. This is to be used for evacuation purposes, access by the fire fighting vehicles and free from any kind of storage with exceptions for electricity substation and a pump house. A fire wall constructed must meet the FRL requirements. The materials used should not easily collapse from the heat caused by fire. Since the lift will connect to more than two levels, it should be separated from the structure. 3.2.3 Protection of Openings(BCA VOL 1 195) The building should have a minimum of two exits with a direct access to a road or an open arena. The open space should be within the structure, be accessible and not used as a storage facility. The access road must be free from any obstruction for emergency vehicles, enable pedestrians to easily move between the building and the access road. The maximum area for atria is 5000 square meters. Wall openings should be protected by automatic doorways and windows. Elements of the structure should not allow fire to reach the exit, public corridors, and adjacent buildings. Heat and smoke that arise during fire should be limited to allow the time needed to exit the building, the purpose of the structure, and access to fire systems placed in the structure. 3.3.0 Accessibility and Egress The BCA requirements for access and egress look at the provisions made for escape exits to be constructed and considerations made for the disabled. 3.3.1 Provisions for Escape (BCA VOL 1 153) In general, not less than two exits must be

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.